Series DCT1000DC Dust Collector Timer Controller
For Low Voltage Applications
Simplify your on-demand cleaning requirements with the Series DCT1000DC Dust Collector Timer Controller. Relying on one timer board for on demand and continuous cleaning applications, the DCT1000DC eliminates external devices such as pressure switches, relays and timers.
The DCT1000DC accepts 10-30 VDC power. The units modular design allows for use as a continuous cleaning control or on demand cleaning control using the optional DCP plug-in pressure module. A 4-20 mA process output is integral to the DCP pressure module, eliminating the need to purchase an expensive process transmitter. A solenoid fault light on the DCT1000DC notifies the operator when a solenoid valve fails to activate properly.
The DCT1000DC is the same size for 6, 10 and 22 channels. One board size allows the standardization on one enclosure.
Product Applications
- Dust collection
- Pneumatic conveying
Models & Ordering
Specifications
- DCT1000DC TIMER CONTROLLER:
- Output Channels:
- 6, 10 & 22 channels.
- Power Requirements:
- 10-30 VDC.
- Power Consumption:
- 5 W.
- Solenoid Supply:
- 3A maximum per channel.
- Fuse:
- 3 A @ 250 VAC.
- Temperature Limits:
- -40 to 140°F (-40 to 60°C).
- Storage Temperature Limits:
- -40 to 176°F (-40 to 80°C).
- On-time:
- 10 msec to 600 msec, 10 msec steps.
- On-time Accuracy:
- ±10 msec.
- Off-time:
- 1 second to 255 seconds, 1 second steps.
- Off-time Accuracy:
- ±1% of the value or ±50 msec, whichever is greater.
- Weight:
- 1 lb, 3.0 oz (538.6 g).
- Agency Approvals:
- CE.
- DCP PRESSURE MODULE:
- Pressure Ranges:
- 10" w.c. or 20" w.c.
- Temperature Limits:
- -40 to 140°F (-40 to 60°C).
- Pressure Limits:
- 10 psi (68.95 kPa).
- Pressure Limits (differential):
- 10 psi (68.95 kPa).
- Accuracy:
- ±1.5% F.S. @ 73°F (22.8°C).
- Output Signal:
- 4-20 mA.
- Alarm Contacts:
- 1.5A inductive load, 3A resistive load @ 30 VAC or 40 VDC.
- Process Connections:
- Two barbed connections for use with 1/8" (3.18 mm) or 3/16" (4.76 mm) I.D. tubing.
- Weight:
- 5.5 oz (155.9 g).
Features
- 10 to 30 VDC power requirement for low voltage applications
- Standard mounting holes to other dust collector controllers for use in existing installations
- Able to automatically detect any channel expander connected
Options
- WP-Weatherproof Housing Only
- WPP-Weatherproof Housing with Pressure Ports
- WPPS-Weatherproof Housing with Pressure Ports, Three Position Rotary Switch Installed
- EXPL-Explosion-proof Housing
Stacked in Enclosure
Accessories
Model Number | Description | Usually Ships* | Price | Order | |
---|---|---|---|---|---|
![]() |
DPMA-402 | LCD Digital panel meter, loop powered 4 to 20 mA, red segments. | 7-8 Weeks | $152.00 | Order |
Model Chart
EXAMPLE | DCT | 1006DC | AT | Series DCT1006DC-AT Dust Collector Timer Controller, 6 channel, with aluminum tag. |
SERIES | DCT | Dust Collector Timer Controller | ||
CONTROLLER TYPE | 1006DC 1010DC 1022DC |
6 Channel 10 Channel 22 Channel |
||
OPTIONS | AT COC COO DCP100A DCP200A EXPL NCO ST WP WPP WPPS WPPH WPPHS |
Aluminum Tag Certificate of Conformance Certificate of US Origin Pressure Module, 10" w.c. Pressure Module, 20" w.c. Explosion-proof Housing NAFTA Certificate of Origin Stainless Steel Tag Weatherproof Enclosure Weatherproof Enclosure with Pressure Connection Weatherproof Enclosure with Pressure Connection & Switch Weatherproof Enclosure with Horizontal Pressure Connection Weatherproof Enclosure with Horizontal Pressure Connection & Switch |
Approvals
Drawings
Questions
- Question
- Is there a limit to the length of tubing used on the DCP100A pressure Module?
- Answer
- There is no limit to the length of tubing you connect to the DCP100A pressure module. It can be as long or as short as you need for your application. However, please note, that the longer you make the tubing, the longer the response time of the DCP100A will be.
Photo Downloads
You must be logged in to view this content.Click here to login to your account.